PowerBuilder |
Controls & UI |
2025 |
3711 |
The dropdown menu of the RibbonBar button doesn't get the focus when it's opened.
|
13554,
Community
|
PowerBuilder |
Controls & UI |
2025 |
3711 |
When the MenuToRibbonBar and TabbedView features are enabled, some items on the sheetlist or the whole sheetlist disppears.
|
13558
|
PowerBuilder |
Controls & UI |
2025 |
3711 |
When the HidePanelText and HideTabHeader properties are enabled, the RibbonBarAutoHeight is not working correctly.
|
13591
|
PowerBuilder |
Controls & UI |
2025 |
3711 |
PowerBuilder 2025 doesn't load the external images from PBD.
|
13616
|
PowerBuilder |
PowerScript |
2025 |
3711 |
PowerBuilder 2025 Menu painter change corrupts Menu object's source code.
|
13574
|
PowerBuilder |
PowerBuilder IDE |
2025 |
3711 |
"Go To -> Next Marker" doesn't go to the marker next to the current cursor position.
|
13189
|
PowerBuilder |
Controls & UI |
2025 |
3711 |
The centering feature in PowerBuilder 2025 doesn't work on any secondary or extended displays.
|
13672
|
PowerBuilder |
DataWindow |
2025 |
3711 |
When several tables have the same column name, DB name always uses the name of the first table.
|
13607
|
PowerBuilder |
PowerBuilder Compiler |
2025 |
3711 |
When the "Allow dashes in identifies" is unchecked, the Solution compiler reports syntax error when compiling code with dashes.
|
13677
|
PowerBuilder |
PowerBuilder IDE |
2025 |
3711 |
Changing the Deploy properties of pbproj files is not saved.
|
13596
|
PowerBuilder |
PowerBuilder Compiler |
2025 |
3711 |
When an empty PBL includes a PBR file containing duplicate resources, the compilation process exits during PBD generation without any errors.
|
13744
|
PowerBuilder |
Other |
2025 |
3711 |
Run the a .NET DataStore project after Build and Deploy, then close the console and the project. Right-click to run the project again and it crashes the PowerBuilder IDE.
|
13660
|
PowerBuilder |
PowerClient |
2025 |
3711 |
URL of the timestamp server on PowerServer Signing config resets to the default digicert url.
|
13572
|
PowerBuilder |
PowerBuilder IDE |
2025 |
3711 |
If the .pbsln file is Read-only, PowerBuilder crashes when opening the Solution.
|
13827
|
PowerBuilder |
PowerScript |
2025 |
3711 |
Calling update() fails after deleting multiple rows with binding.
|
11514
|
PowerBuilder |
PowerBuilder Compiler |
2025 |
3711 |
Running the Solution project fails after saving an existing object with another name.
|
13854
|
PowerBuilder |
DataWindow |
2025 |
3711 |
Datawindow sliding fields are not printed correctly when the HighDpiMode property value is not 0.
|
13865
|
PowerBuilder |
PowerBuilder IDE |
2025 |
3711 |
In the Solution mode, after copying and pasting an OLE object, the user event of the copied object is lost.
|
13857
|
PowerBuilder |
PowerBuilder IDE |
2025 |
3711 |
String concatenation works without a + sign in the Solution mode in PowerBuilder 2025.
|
13855
|
PowerBuilder |
DataWindow |
2025 |
3711 |
Using editmask in DataWindow, the Year value of the Date field changes after typing in the last digit on 64-bit applications.
|
13162
|