PowerBuilder |
PowerScript |
2022 R3 JP |
3409 |
If "\" is included in the Mask property, the characters display incorrectly because the default Mask is used instead.
|
12938
|
PowerBuilder |
DataWindow |
2022 R3 JP |
3409 |
Changing the default printer does not take effect in real time in PB2022
|
12749
|
PowerBuilder |
PowerClient |
2022 R3 JP |
3409 |
When a Datawindow with a blank value is Saveas to a Excel file, the ISBLANK() function in the Excel file returns TRUE.
|
12715
|
PowerBuilder |
Controls & UI |
2022 R3 |
3289 |
RichTextEdit CopyRTF returns an empty string if you copy and paste an image to RTF.
|
11141
|
PowerBuilder |
Controls & UI |
2022 R3 |
3356 |
The Activate event of the current window is triggered multiple times when a ribbon bar category is clicked, but only when a theme is applied and the ribbon is minimized.
|
11208
|
PowerBuilder |
PowerScript |
2022 R3 |
3289 |
MAPI mailSession mailReadMessage is marking message as read even if the argument mark is set to False.
|
11152
|
PowerBuilder |
PowerScript |
2022 R3 |
3289 |
WebBrowser EvaluateJavascriptSync returns 'test' when passing null or "" to PB event.
|
--
|
PowerBuilder |
PowerBuilder IDE |
2022 R3 |
3289 |
If you start PowerBuilder via commands, PowerBuilder may give incorrect prompt such as "There are no deployable projects in this target. Do you want to create one now?" even if there are deployable projects.
|
10849
|
PowerBuilder |
Controls & UI |
2022 R3 |
3289 |
When AutoCompleteMode is Suggest and lines in dropdown id not 0, the dropdown filter height is wrong after switching focus with tab key.
|
11225
|
PowerBuilder |
PowerScript |
2022 R3 |
3289 |
Getting different results when reading a computed column's value using dot notation (.object) and GetItemString.
|
5268
|
PowerBuilder |
Database |
2022 R3 |
3289 |
The ADO.NET SQL Server Driver specific parameters Command Timeout and Connection Timeout configured in the IDE > Database painter have no effect.
|
11221
|
PowerBuilder |
PowerBuilder IDE |
2022 R3 |
3289 |
PB IDE will crash when DataWindow Painter retrieves data with DateTime parameter, using MS SQL Server ADO.NET and DisableBind = 0.
|
11305
|
PowerBuilder |
Controls & UI |
2022 R3 |
3289 |
SMTPClient uses wrong creation time in the header.
|
11315
|
PowerBuilder |
Controls & UI |
2022 R3 |
3289 |
Menu error when setting the tab order.
|
9722
|
PowerBuilder |
Controls & UI |
2022 R3 |
3289 |
HTTPClient Response Content-Type detection fails when Content-Type header includes additional data after encoding.
|
11117
|
PowerBuilder |
PowerScript |
2022 R3 |
3356 |
Memory keeps increasing when GetFullState is executed.
|
11591
|
PowerBuilder |
Controls & UI |
2022 R3 |
3356 |
When TabbedView is enabled, windows opened via OpenSheetWithParm(Layered!) do not size to the MDI frame properly.
|
11656
|
PowerBuilder |
Other |
2022 R3 |
3356 |
Images included in resources are not displayed on the menu toolbar if the image file name contains multi-byte characters.
|
11608
|
PowerBuilder |
DataWindow |
2022 R3 |
3356 |
It is difficult to click the data point with modern graph.
|
11768
|
PowerBuilder |
Controls & UI |
2022 R3 |
3356 |
The SMTPClient BCC email address is visible to the TO recipients.
|
11547
|