| PowerBuilder |
Runtime |
2025 R2 |
6464 |
Customizing the color of symbols does not take effect in the PowerBuilder 2025 R2 code editor.
|
Community,
15108
|
| PowerBuilder |
PowerBuilder IDE |
2025 R2 |
6430 |
The descendant object clears the ancestor instance variable's initial value.
|
14725
|
| PowerBuilder |
PowerBuilder IDE |
2025 R2 |
6430 |
The modal focus is lost and sheets are incorrectly enabled in multi-layer window stack.
|
14783
|
| PowerBuilder |
PowerClient |
2025 R2 |
6430 |
PowerServer/PowerClient project compilation fails when a PBR that contains DataWindow is included in the PBL.
|
14690
|
| PowerBuilder |
Solution |
2025 R2 |
6430 |
PowerBuilder IDE crashes when the prompt to add script to the application's open event is dismissed.
|
14838
|
| PowerBuilder |
Other |
2025 R2 |
6430 |
SyntaxFromSQL causes the application to crash in 64-bit mode with Informix.
|
14849
|
| PowerBuilder |
Database |
2025 R2 |
6430 |
Failed to execute E-SQL when full build with ADO.NET for PostgreSQL.
|
14691
|
| PowerBuilder |
PowerBuilder IDE |
2025 R2 |
6430 |
PowerBuilder IDE crashes when clicking the costumized item on the toolbar.
|
14881
|
| PowerBuilder |
Other |
2025 R2 |
6430 |
PBDebug does not work when used in the shortcut of the application EXE program.
|
13675
|
| PowerBuilder |
PowerScript |
2025 R2 |
6430 |
The LibraryExport function does not export the corresponding DataWindow syntax when the PBL full path is not specified.
|
14699
|
| PowerBuilder |
Controls & UI |
2025 R2 |
6430 |
The text on the Picture Button disappears after overlapped by another window when no picture is assigned.
|
14945
|
| PowerBuilder |
Controls & UI |
2025 R2 |
6430 |
When Theme is enabled, the text on the Picture Button disappears when dragging the window.
|
14409
|
| PowerBuilder |
Solution |
2025 R2 |
6430 |
In a Solution project, after an external PBD is added to the project, SVN Update fails and reports "Failed to update library: "xxx.pbd"" on the external PBD file.
|
14960
|
| PowerBuilder |
Solution |
2025 R2 |
6430 |
In PowerBuilder 2025, converting Workspace to Solution fails without any error message when the application contains a non-visual object with embedded non-visual objects.
|
14832
|
| PowerBuilder |
PowerScript |
2025 R2 |
6430 |
SELECTBLOB returns an incorrectly large result from an ASE database using the UTF-8 charset.
|
Community
|
| PowerBuilder |
Database |
2025 R2 |
6430 |
After connecting to SQL Server via ODBC, an ESQL statement fails when using the CONVERT function to convert to datetime if the milliseconds value contains 0.
|
14906
|
| PowerBuilder |
PowerBuilder IDE |
2025 R2 |
6430 |
Using Git for source control, after switching Runtime version and restarting PowerBuilder IDE, the IDE reports "Fatal Disk Error, Retry?" when opening any object.
|
14942
|
| PowerBuilder |
PowerBuilder IDE |
2025 R2 |
6430 |
The elapsed time reported in the end after searching in the application is misleading.
|
14915
|
| PowerBuilder |
PowerBuilder IDE |
2025 R2 |
6464 |
If the code line contains semicolons(;), Format document/selection does not work well.
|
14888
|
| PowerBuilder |
Other |
2025 R2 |
6464 |
When debugging an application in the IDE, Setlibrarylist returns 1.
|
15127
|