PowerBuilder |
PowerScript |
2022 |
1892 |
Compare the wparam parameter in a custom event with a constant using CHOOSE CASE. The return value is false.
|
1090
|
PowerBuilder |
DataWindow |
2022 |
1892 |
Export the data in DataWindow object into JSON, and then import the JSON into another DataWindow object. The values of DateTime and Time in these two objects are different.
|
6406
|
PowerBuilder |
DataWindow |
2022 |
1892 |
If using PowerBuilder JP version Build 20H4 or later in Windows 10 OS, when the last IME mode was on, the initialization switch mode needs to be reset even if Microsoft IME is closed.
|
8333
|
PowerBuilder |
Compiler |
2022 |
1892 |
When running the Run_PBA.bat file, errors occur during import or compilation, and the source code cannot be merged.
|
8769
|
PowerBuilder |
DataWindow |
2022 |
1892 |
In the OS where a comma is used instead of a decimal point in decimal numbers, the comma will be missing, which could result in significant increase of the number.
|
8836
|
PowerBuilder |
Controls & UI |
2022 |
1892 |
The window size on the PowerBuilder IDE design interface is inconsistent with the size when demo is running. The actual window interface is wider and longer.
|
8888
|
PowerBuilder |
DataWindow |
2022 |
1892 |
In PowerBuilder 2022, when saving data to a PDF file with NativePDF, the font size and border width in the PDF file are displayed differently.
|
8899
|
PowerBuilder |
Runtime |
2022 |
1892 |
When running the 64-bit exe program, "Error accessing external object property" is displayed on the window.
|
8903
|
PowerBuilder |
IDE |
2022 |
1892 |
In PowerBuilder 2022 GA, the icon is enlarged in source control, but it is not modified synchronously in Library Painter. Since there is not enough space for the new icon, it cannot be fully displayed in Library Painter.
|
8952
|
PowerBuilder |
PowerScript |
2022 |
1892 |
The GetInstalledRuntimes function is invalid, causing compilation errors when running the code.
|
8987
|
PowerBuilder |
Controls & UI |
2022 |
1892 |
When directly running the demo, only a blank window opens, but no message box pops up. The icon property is set in the open event, so that the show event cannot be triggered.
|
8998
|
PowerBuilder |
IDE |
2022 |
1892 |
In 64-bit OS, if you input a character in the EditMask control, and then press the tab key or click the first input box in EditMask with dates, the number or character cannot be input.
|
8984
|
PowerBuilder |
DataWindow |
2022 |
1892 |
The RichText DataWindow column is empty, but it takes up several lines in Nested Report.
|
8358
|
PowerBuilder |
DataWindow |
2022 |
1892 |
The size of barcode label distorts when saving data to a PDF file with NativePDF.
|
9028
|
PowerBuilder |
DataWindow |
2022 |
1892 |
In 64-bit OS, the application crashes when setting the Transparency of a DataWindow.
|
9141
|
PowerBuilder |
DataWindow |
2022 |
1892 |
When resizing the first DataWindow or switching focus between columns, DataWindow creates hundreds of GDI object.
|
9171
|
PowerBuilder |
IDE |
2022 |
1892 |
When choosing the type of PBNative , if you select the Log All Activity check box to set a file as the log, PowerBuilder IDE will crash.
|
9188
|
PowerBuilder |
DataWindow |
2022 |
1892 |
The template for exporting XML file is set in DataWindow, but the first line of the XML file ends with character LF instead of CRLF.
|
9220
|
PowerBuilder |
Controls & UI |
2022 |
1892 |
In 64-bit OS, there is a lack of shortcut message distribution for Ribbonbar. As a result, the Ribbonbar is unable to receive shortcut messages, and the shortcut ALT+S and ALT+C in RibbonBar cannot respond.
|
9274
|
PowerBuilder |
IDE |
2022 |
1892 |
The change of the region settings will cause the changes in date format so that the program cannot be read to the end correctly, which makes the array storing the date out of bounds, causing IDE crash.
|
8999
|